Clogging in cooling tower fills is a common issue that reduces heat transfer efficiency, increases energy consumption, and can lead to operational failures. The primary reasons for clogging include:

1. Scaling (Mineral Deposits)

  • Cause: High concentrations of calcium, magnesium, silica, and carbonate in water precipitate and form hard deposits.
  • Effect:
    • Blocks water flow through fill media.
    • Reduces surface area for heat exchange.
    • Common in high-hardness water or poor blowdown control.

2. Biological Growth (Algae, Bacteria, Biofilms)

  • Cause: Warm water and sunlight promote algae, bacteria (including Legionella), and slime formation.
  • Effect:
    • Biofilms stick to fill surfaces, trapping debris.
    • Can lead to Legionella outbreaks if untreated.
    • Reduces airflow and water distribution.

3. Suspended Solids & Debris

  • Cause: Dirt, sand, rust, and airborne contaminants (dust, leaves) enter the system.
  • Effect:
    • Accumulates in fill media, blocking water passages.
    • Common in open cooling towers exposed to the environment.

4. Corrosion By-products

  • Cause: Rust (iron oxide), copper oxides, and other metal particles from corroded pipes.
  • Effect:
    • Forms sludge that clogs fills.
    • More severe in systems with low pH or high chlorides.

5. Poor Water Treatment & High Cycles of Concentration (COC)

  • Cause: Improper chemical dosing or infrequent blowdown leads to high TDS levels.
  • Effect:
    • Accelerates scaling and fouling.
    • Increases deposit formation in fills.

6. Oil & Grease Contamination

  • Cause: Leaking pumps, gearboxes, or process fluid leaks introduce oil into water.
  • Effect:
    • Coats fill surfaces, reducing heat transfer.
    • Traps dirt and promotes microbial growth.

How to Prevent Clogging in Cooling Tower Fills?

◉ Regular Cleaning:

  • Use high-pressure water jets or chemical cleaning (acid/alkaline washes).
  • Remove biofilm with biocides (chlorine, bromine, non-oxidizing biocides).

◉ Proper Water Treatment:

  • Use scale inhibitors, dispersants, and anti-foulants.
  • Maintain pH (7.0–9.0) and control TDS (<3,000 ppm).

◉ Filtration:

  • Install side-stream filters or sand filters to remove suspended solids.

◉ Blowdown Management:

  • Optimize cycles of concentration (COC) to prevent scaling.

◉ Corrosion Control:

  • Use corrosion inhibitors (e.g., phosphates, zinc, molybdate).

◉ Legionella Prevention:

  • Shock treatment with chlorine or ozone.
  • Regular microbiological testing.

Signs of Clogged Cooling Tower Fills

◉ Reduced cooling efficiency (higher outlet water temps)
◉ Increased energy consumption (pump/fan works harder)
◉ Uneven water distribution (dry spots in fill)
◉ Visible deposits or algae growth